Remove and Replace Cisco NIM-SSD or NIM-HDD

Figure 5-18

Cisco NIM-HDD LEDs

Table 5-3
Table 5-3
LED
EN (Enabled)
HDD0
HDD ACT
HDD1
Remove and Replace Cisco NIM-SSD or NIM-HDD
This section explains how to remove a NIM-SSD or NIM-HDD from the router chassis and replace it
with a new external NIM-SSD or NIM-HDD.
Plugging additional SSD Carrier Card NIMs into a bay powers off the module. Power down the
NIM-SSD module and wait for the power LED to turn off before removing the module or removing and
replacing new SSD drives.
To deactivate and reactivate a NIM, see the
section in the Software Configuration Guide for Cisco 4000 Series ISRs.
Hardware Installation Guide for Cisco 4000 Series Integrated Services Routers
5-22
HDD in the NIM Chassis
shows the LED description for the NIM-HDD.
LED Description for NIM-HDD
Color
Green
Amber
Off
Green
Amber
Green
Green
Amber
Chapter 5
Install and Upgrade Internal Modules and FRUs
Description
The module is powered on and is functioning
correctly.
Module has some failure.
Default when module is powered on for the first
time. Persistent until changed by the host
software.
HDD0 is present.
Fault detected on HDD0.
Activity on HDD0 and HDDI
HDD1 is present.
Fault detected on HDD1.
"Deactivating and Reactivating a SSD Carrier Card
NIM"