4.5 Ethernet Virtual Loop with All Panels on Common IP Subnet

Figure 16: Ethernet Virtual Loop (EVL) with All Panels on Common IP Subnet
DIP Switch Settings:
SW3: ON
SW9: ON
SW1 &10: ON : OSDP
SW1 &10: OFF: Wiegand
SW2: 4-8: OFF
Notes:
50
www.honeywell.com
Terminal
MPA2
Primary
MPA2
Panel
(Secondary)
EG
EG
DIP Switch Settings:
SW3: OFF
SW9: ON
SW1&10: ON: OSDP
SW1&10: OFF: Wiegand
SW2: 4-8: OFF
Ethernet Connection with EVL Loop
1. The Network must provide DHCP server (or use dedicated
Network configuration with a router, as shown in next section).
2. The Network must provide firewall protection from
unauthorized access.
3. EVL connected MPA2 downstream panel communication has
not been evaluated by UL.
ETHERNET
SWITCH
MPA2
NetAXS-123
Panel
Panel
(Secondary)
(Secondary)
DIP Switch Settings:
S1-S5: Panel Address
S6: OFF
S7: OFF
S8-S9: ON: 485 Termination ON
To NETWORK
CAT 7 S/FTP
NetAXS-123
Panel
(Secondary)
EG
EG