Honeywell ISA100 Gen X User Manual page 44

Radio module
Table of Contents

Advertisement

ISA100_NOTIFY_ALARM_REGEN_END
The Sensor generates alarm regen end message to the Radio board, one per category of alarms
basis, when all the pending alarms are issued. The 1-byte data value carries the 1- byte
category value.
Note: The Radio board also sends an acknowledgement to the sensor when it receives the
alarm regen end message.
Synch Byte
Packet
Length
0x5A
0x04
ISA100_ADD_UAP_ALARM
This message is generated by the Sensor board to send an alarm to the system. This message
is specially treated from the other ASL message because this message needs to be added to
ARMO queue present in the Radio board. The data contains the standard alarm message as
described in the ISA100 standard.
Synch Byte
Packet
Length
0x5A
0x0F
Byte 1,
Byte 0
Byte 2
UAP ID
SOID
44
Packet
Packet
Class
Type
0x30
0x8D
Packet
Packet
Class
Type
0x30
0x1E
Byte3
Byte4
Byte4
Alert
Alert
Aler
Class
Directio
t
n
Typ
e
ISA100 Gen X Radio Module User's Guide
Honeywell
Packet
Packet
Check
ID
size
sum
0x01
0x00
XX
Packet
Packet
ID
size
0x01
0x0B
Byte5
Byte6
Alert
Alert
Priorit
Categor
y
y
Check
sum
XX
Data Bytes
Check
Check
0-N
sum
sum
Description
XX
XX
Below
Byte7
Byte8-ByteN
Alert value length
Alert Value
Release Independent
April 2018