ISA100_CONTRACT_TERMINATE
This message is sent by the Sensor board to the Radio board to delete an existing contract. The
data contains the contract termination message, which is 2-byte Contract Id.
Synch
Packet
Byte
Length
0x5A
0x07
ISA100_NOTIFY_DELETE_CONTRACT
This message is sent by the Radio board to the Sensor board to delete the contract once the
terminate contract confirmation is received from the system manager. The data contains the
contract delete message, which is 2-byte Contract Id.
Synch
Packet
Byte
Length
0x5A
0x06
Alarm Related Messages
ISA100_NOTIFY_ALARM_REGEN_BEGIN
The Radio issues Alarm regen begin message to the Sensor board when the system issues the
Alarm recovery to the Radio board. The Sensor board generates all the pending alarms when
this message is received. There are 4 such alarms generated each for 4 message categories
(communication, process, device diagnostics, and security). The 1- byte data value carries the
alarm category.
Synch Byte
0x5A
Release Independent
April 2018
Packet
Packet
Class
Type
0x30
0x18
Packet
Packet
Class
Type
0x38
0x17
Packet
Packet
Packet
Length
Class
Type
0x05
0x38
0x8C
ISA100 Gen X Radio Module User's Guide
Packet ID
Packet
Data0,
size
Data1
Contract
0x01
0x03
ID
Packet
Packet
Data0,
ID
size
Data1
0x01
0x02
Contract ID
Packet
Packet
ID
size
0x01
0x01
Honeywell
Check
Data2
sum
Operation-
XX
Terminate 0/
Deactivate1/
Reactivate2
Check
Check
sum
sum
XX
XX
Data0
Check
sum
Alert Category
XX
Chec
k sum
XX
Check
sum
XX