8.5.4

Concluding steps

Perform the following steps:
"Installing the server node in the server enclosure" on page 67
Ê
I
If the Global LED is flashing with error message "CPU has been
changed" on display after the system is powered on, please follow the
procedure below.
Ê Restart the system and wait until the screen output appears.
Ê Press the [F2] function key.
Ê If a password is assigned, enter this password and confirm with the
[Enter] key.
The BIOS setup Main menu will be displayed on the screen.
Ê Select "Commit settings and Exit" on Exit menu.
Confirm LED no flashing.
Ê
This information is only regarding to the change of CPU configuration.
There is no technical problem.
– If applicable, reconnect all external cables.
"Switching on the server node" on page 69
"Updating or recovering the system board BIOS and iRMC" on page 77
applicable)
"Controls and indicators on the server node" on page 448
"Resetting the error status after replacing CPUs" on page 103
"Enabling SVOM boot watchdog functionality" on page 88
CX2550/60/70 M4