Chapter 5
Maintenance and Troubleshooting
Alarm
Rx1_Data
Rx2_Data
Rx3_Data
Rx4_Data
IntComm
Alarm
Node Data
Alarms Specific to GS7000 Nodes
Alarm
NdTxPwr
NdRxPwr
136
Function
Possible Causes
Loss of data for
Rx1
Loss of data for
Rx2
Loss of data for
Rx3
Loss of data for
Rx4
Internal
communication
error
Forced alarm
Node data valid
or invalid
Function
Possible Causes
Tx loss of output
power
Rx loss of
output power
Degraded signal
Low input power
Degraded transmitter
Wrong mode selected
Degraded signal
Low input power
Degraded transmitter
Wrong mode selected
Degraded signal
Low input power
Degraded transmitter
Wrong mode selected
Degraded signal
Low input power
Degraded transmitter
Wrong mode selected
Hardware failure
User is forcing an
alarm
Broken fiber
Transmitter failure
Broken cable
Transmitter failure
Low or no input
power at node
receiver input
Node receiver
hardware failure
Possible Solutions
Check, clean fiber
Check transmitter
output power
Check, clean fiber
Check transmitter
output power
Check, clean fiber
Check transmitter
output power
Check, clean fiber
Check transmitter
output power
Replace module
Check for other
alarms indicating
fault elsewhere
Disable "Alarm"
control
Check fiber
Check transmitter
Possible Solutions
Check cable
Check transmitter
Replace module
Check for other
alarms indicating
fault elsewhere