View

Job view
Default level
3: Manage level
Parameters
time time-id: Time setting entry, where time-id is an integer ranging from 1 to 10. A scheduled job can
be specified with up to 10 time setting entries.
one-off: Specifies that the specified command runs only once.
repeating: Specifies a recurring time schedule.
delay time: Specifies the delay time for executing the command, in the hh:mm format or mm format.
When the time argument is in the hh:mm format, the hh value ranges from 0 to 720, and the mm
value ranges from 0 to 59. When the hh value is 720, the mm value can be only 00.
When the time argument is in the mm format, the mm value ranges from 1 to 43,200. That is, the
maximum value of the delay timer is 30 days.
Changing a clock setting does not affect the schedule set by using the time delay command.
command command: Command to run at a specified time.
Description
Use the time delay command to configure a scheduled job to be executed after a delay time.
Use the undo time command to remove the configuration.
NOTE:
The commands in a scheduled job must be in the same view.
Every job can have up to 10 commands.
Examples
# Save the configuration file a.cfg five minutes later.
<Sysname> system-view
[Sysname] job saveconfig
[Sysname-job-saveconfig] view monitor
[Sysname-job-saveconfig] time 1 one-off delay 5 command save a.cfg
# Save the configuration file a.cfg every five minutes.
<Sysname> system-view
[Sysname] job saveconfig
[Sysname-job-saveconfig] view monitor
[Sysname-job-saveconfig] time 1 repeating delay 5 command save a.cfg