Patch Location - HP A7500 Series Command Reference Manual

Fundamentals
Hide thumbs Also See for A7500 Series:
Table of Contents

Advertisement

Description
Use the patch load command to load the patch file on the storage media (the Flash) to the memory patch
area.
If you execute the command with providing the filename of a patch package, the system will load
the patch from the patch package.
If you execute the command without providing the filename of a patch package, the system will load
the patch from a patch file.
The system loads the patch file from the Flash by default.
Before executing the command, save the patch files to the specified directory. Note that the following
rules apply:
In standalone mode, if you load patches from patch packages, save the patch packages to any
directory on the active MPU.
In standalone mode, if you load patches from patch files, save the patch files for the active MPU or
LPUs to the root directory of the Flash on the active MPU, and save the patch files for the standby
MPU to the root directory of the Flash on the standby MPU.
In IRF mode, if you load patches from patch packages, save the patch packages to any directory on
the active MPU of the IRF fabric.
In IRF mode, if you load patches form patch files, save the patch files to root directories of the
member switches' storage media: save the patch files for the active MPU or LPUs of each member
switch to the root directory of the Flash on the local active MPU, and save the patch files for the
standby MPUs of each member switch to the Flash on the local standby MPU.
Examples
# In standalone mode, load the patch file from a patch file for the standby board in slot 1.
<Sysname> system-view
[Sysname] patch load slot 1
# In standalone mode, load the patch file from a patch package for the standby board in slot 1. ()
<Sysname> system-view
[Sysname] patch load slot 1 file flash:/patchpackege.bin
# In IRF mode, load the patch file from a patch file for the card in slot 3 on the IRF member switch with
member ID of 1.
<Sysname> system-view
[Sysname] patch load chassis 1 slot 3
# In IRF mode, load the patch file from a patch package for the card in slot 3 on the IRF member switch
with member ID of 1.
<Sysname> system-view
[Sysname] patch load chassis 1 slot 3 file flash:/patchpackege.bin

patch location

Syntax
patch location patch-location
View
System view
132