A.5
Assembling the line supply terminal for the drive
Drive variant
Assembling procedure
SINAMICS V70
1. Strip the specified length (see illustra-
FSA
2. Insert the stripped end into the pin-
3. Crimp the terminal using a crimping
SINAMICS
•
1. Strip the specified length (see illustra-
V70
FSB/FSC/FSD
SINAMICS
•
2. Insert the stripped end into the fork-
V60
3. Crimp the terminal using a crimping
A.6
Cutting reserved holes in the MCP
There are four variants of MCP, two horizontal variants and two vertical variants. On the horizontal variant with override
switches, there are three reserved holes with a standard diameter of 16 mm, and on the horizontal variant with a reserved
slot for the handwheel, there are two reserved holes with a standard diameter of 22.5 mm; on each vertical variant, there are
four holes with a standard diameter of 16 mm. They are available for you to install necessary devices according to your own
needs:
Commissioning Manual
01/2017
tion) of the insulation at the end of the
wire.
type terminal.
tool, and cut off the excess part of the
wire.
tion) of the insulation at the end of the
wire.
type terminal.
tool. (Note: Coat any exposed wires
with tin.)
Illustration
483