Ethernet Interface - X130 - Siemens SINUMERIK 808D ADVANCED Commissioning Manual

Hide thumbs Also See for SINUMERIK 808D ADVANCED:
Table of Contents

Advertisement

Connecting the inverter or servo spindle drive (bipolar)
+/- 10 V analog voltage
1)
0 V signal
2)
Use twisted pair cables for signals A/A_N, B/B_N, Z/Z_N, and +5 V/M.
3)
4.2.13

Ethernet interface - X130

Pin assignment
Type
8-pin RJ45 socket
Cable
Type: Ethernet cable
Illustration
Note
The length of the Ethernet cable must be less than 30 m or the communication will be unstable.
Commissioning Manual
01/2017
Pin
Signal
1
MX1+
2
MX1-
3
MX2+
4
MX3+
5
MX3-
6
MX2-
7
MX4+
8
MX4-
Comment
Data 1
Data 1
Data 2
Data 3
Data 3
Data 2
Data 4
Data 4
101

Advertisement

Table of Contents
loading

Table of Contents