Establishing a connection via the RS232 interface (PPU160.2 only)
Note
The RS232 interface is available on the PPU160.2 only.
Proceed through the following steps to establish a connection between the control system and a computer:
+
↓
48
10.
Enter the IP address for the control system in the communication setting window, for exam-
ple:
Note that the IP address entered here must be the same as that you have set on the PPU.
11.
Double-click this symbol in the communication setting window to establish a connection to
the specified IP address.
Wait until the information of the connected control system is identified as follows, and then
the connection is ready.
1.
Connect the control system with the computer using an RS232 cable.
2.
Select the system data operating area on the PPU.
3.
Press these two softkeys in succession to open the following communication setting win-
dow.
4.
Use this softkey to select a communication baud rate. The control system supports the
following baud rates:
9.6 kbps
•
19.2 kbps
•
38.4 kbps
•
57.6 kbps
•
115.2 kbps
•
5.
Activate the RS232 connection with this softkey.
No modifications to the settings are possible in this state.
The active or inactive state is retained even after a power-on (except when you start the
system with the default data).
In the lower right corner of the screen, the
puter via the RS232 interface is active.
icon shows that the connection to the com-
Commissioning Manual
01/2017