Local variable definition
Inputs
Name
nodef
ASUP1_trigger
ASUP2_trigger
Outputs
Name
ASUP1Run
ASUP2Run
Err1
Err2
Occupied global variables
IniASUP1
IniASUP2
DelPswStart
DelPswSel
Relevant machine data
No.
10702
11602
11604
20116
No.
14512 [19].2
Example for calling subroutine 46
182
Type
Description
BYTE
Reserved
BOOL
Start ASUP1 (rise edge)
BOOL
Start ASUP2 (rise edge)
Type
Description
BOOL
Indicates whether ASUP1 is running
BOOL
Indicates whether ASUP2 is running
BOOL
ASUP1 error
BOOL
ASUP2 error
M229.0
Mark of ASUP1 initialization
M229.1
Mark of ASUP2 initialization
M228.0
Start to delete password
M228.1
Delete password select
Name
IGNORE_SINGLEBLOCK_MASK
ASUP_START_MASK
ASUP_START_PRIO_LEVEL
IGNORE_INHIBIT_ASUP
Value
Description
1
The control system will not delete the password after NC restart
0
The control system will delete the password after NC restart