BOP display
Display
Example
8.8.8.8.8.8
.
S-2
S-3
S-4
S-Run
Para
Data
Func
S-Axx
S-LAxx
The subsequent alarms are displayed every two seconds.
1)
472
Description
Initializes the drive (drive self-
testing at power-on) and stay for
about one second during the pro-
cess
Precharges the drive (waiting for
the 220 V mains power)
Waits for drive enable from terminal
65 at X6
Waits for pulse enable from termi-
nals ENA+ and ENA- at X5
Drive is running properly
Editable parameter group
Read-only parameter group
Function group
Displays an alarm code associated
with a fault existent in the drive
system
Displays the first detected alarm
when more than one error occur at
the same time (The alarm number
always contains a letter "L".)
Preconditions for display of normal status
No error code appears
No power supply (24 VDC) fault
No power supply (24 VDC) fault
No alarm code appears
No error code appears
No power supply (24 VDC or 3 AC 220 V to 240
V) fault
No alarm code appears
No power supply (24 VDC or 3 AC 220 V to 240
V) fault
No alarm code appears
Terminal 65 has been enabled
No power supply (24 VDC or 3 AC 220 V to 240
V) fault
No alarm code appears
Terminals 65 has been enabled via an external
24 VDC power supply
Terminals ENA+ and ENA- have been enabled
-
-
-
-
1)