Replace Ups Battery; Equipment Required; Replacement Procedure - Honeywell THOR VM1 User Manual

Vehicle mount computer
Hide thumbs Also See for THOR VM1:
Table of Contents

Advertisement

Replace UPS Battery

The UPS battery in the Thor VM1 is field replaceable. Should the UPS battery fail, it can easily be replaced to minimize down-
time.

Equipment Required

The following equipment is user-supplied:
• Torquing tool capable of measuring inch pounds
• #2 Phillips screwdriver bit

Replacement Procedure

CAUTION - Before replacing the Thor VM1 UPS battery,
1. Place the Thor VM1 on a clean, well-lit surface before
performing the front panel replacement.
2. Shutdown the Thor VM1.
3. Remove the Thor VM1 from the dock.
4.
Disconnect UPS Battery
5. Loosen the twelve (12) captive M3 screws holding the
front panel. Use a #2 Phillips bit.
6. Carefully lift the front panel away from the device
7. Note the orientation of the UPS battery. Lift the UPS
battery out of the battery well and place it outside the
well. Do not pull on the wires attaching the battery to
the Thor VM1 while lifting the battery.
8. Locate the retaining tab on the wiring connector for the
UPS battery. Press on the tab and gently disconnect
the UPS battery wiring from the Thor VM1.
(page 4-60).
Disconnect UPS Battery
2
7
9
5
1
11
13
Wiring
UPS
Connector
Battery
Wiring Connector
with Release Tab
(page 4-60).
4
3
12
Foam
Pads
6
10
8
14
4 - 65

Advertisement

Table of Contents
loading

Table of Contents