Table 1-1 Power Requirements For An Individual Fan; Table 1-2 Slot And Card Symbols; Cards And Slots - Cisco ONS 15600 Reference Manual

Sdh
Hide thumbs Also See for ONS 15600:
Table of Contents

Advertisement

Chapter 1 Shelf and Backplane Hardware
increases appropriately. At initial turn-up, the default fan speed is high until the node initializes. If both
TSC cards fail, the fans automatically shift to high speed. If a single TSC card fails, the active TSC card
will still control the fan speed.
Table 1-1
Condition
Min at 48 V (ambient temperature less than
25 degrees C)
Max at 48 V (ambient temperature greater
than 25 degrees C)

1.11 Cards and Slots

When a card is inserted in a card slot, it will contact the shelf backplane but is not fully installed until
the ejectors are fully closed.
1.11.1 Card Slot Requirements
The ONS 15600 SDH shelf has 14 card slots numbered sequentially from left to right. Slots 1 to 4 and
11 to 14 are reserved for optical (STM-N) traffic cards. These slots can host any of the ONS 15600 SDH
optical cards. Slots 6/7 and 8/9 are dedicated to SSXC cards, and Slots 5 and 10 house the TSC cards.
Each card is keyed to fit only in an appropriate slot for that card. Unused card slots should be occupied
by a filler card (blank faceplate).
Do not operate the ONS 15600 SDH with a single TSC card or a single SSXC card installed. Always
Caution
operate the shelf with one active and one redundant standby TSC card and two SSXC cards.
Shelf assembly slots have symbols indicating the type of cards that you can install in them. Each
ONS 15600 SDH card has a corresponding symbol. The symbol on the card must match the symbol on
the slot.
Table 1-2
Table 1-2
Symbol Color/Shape
Orange/Circle
Purple/Square
Green/Cross
Refer to
All physical connections to the optical cards are made through OGI connectors on the card faceplate.
Table 1-3
78-18400-01
Table 1-1
Power Requirements for an Individual Fan
shows the slot and card symbol definitions.
Slot and Card Symbols
Definition
Any traffic card (STM-16, STM-64, ASAP)
TSC slot; only install ONS 15600 SDH cards with a square symbol on the
faceplate
SSXC slot; only install ONS 15600 SDH cards with a cross symbol on the
faceplate
Chapter 2, "Card Reference,"
lists the number of ports and the line rates for ONS 15600 SDH optical cards.
shows the power requirements for an individual fan in a fan tray.
Watts
Amps
12
0.25
46
0.95
for more information about ONS 15600 SDH cards.
Cisco ONS 15600 SDH Reference Manual, Release 9.0
1.11 Cards and Slots
BTU/Hr.
41
157
1-17