Toshiba Strata CTX Programming Manual page 71

Digital business telephone systems
Hide thumbs Also See for Strata CTX:
Table of Contents

Advertisement

F
IELD
08 Call Forward No Ans
Time
09 Dial Input Timer
10 Delay 1 Ringing Timer
11 Delay 2 Ringing Timer
12 Door Unlock Timer
13 9+11 Judgement Timer
14 Emergency Call Timer
15 ABR Busy Detection
Time
16 Lost Call Timer
17 Lost Call Final Timer
18 DTMF Tone Sending
Time
19 Auto Disconnect
23 System Timer Network
DSS Refresh Timer
Strata CTX Programming - Part 2: CTX WinAdmin Programming 04/03
D
ESCRIPTION
The System Call Forward No Answer timer specifies the time period that a phone
will ring prior to invoking the Call Forward operation.
Possible values: 1~180 sec. (default = 30)
This timer permits dial input for a telephone and trunk using DTMF.
Possible values: 0~60 sec. (default = 20)
This timer specifies the time to wait before applying ringing to the designated
phones.
Possible values: 1~60 sec. (default = 12)
Select the time to wait before applying ringing to the designated phones.
Possible values: 1~60 sec. (default = 24)
Select the length of time to send an electrical signal to a door for releasing the lock.
Possible values: 1~30 sec. (default = 6)
The 9+11 Inter-digital timer provides a timing value (1~30 seconds) for the system
to wait for additional digits to be dialed looking for the 911 or 9+911 dialed codes
for treatment using the E911 procedures rather than normal dialing treatment.
Possible values: 1~30 sec. (default = 5)
The Emergency Call timer sets a time for advancing the call to the next station in a
list of destinations for the call.
Possible values: 10~180 sec. (default = 30)
The Destination Busy Detection timer sets the time to wait while looking for a busy
condition on an external call. If detected, it will trigger the initiation of the Automatic
Busy Redial cycle.
Possible values: 1~30 sec. (default = 5)
The Lost Call timer sets the time that a failed transfer recall will ring on the
originating station prior to attempting to recall a secondary location.
Possible values: 1~600 sec. (default = 180)
The Lost Call Final timer sets the time that a failed transfer recall will ring on the
secondary location before being automatically disconnected.
Possible values: 1~600 sec. (default = 30)
The DTMF tone sending duration for dialing on CO Lines.
Possible values: 80msec (default) or 160msec
Time after which an unsupervised trunk may be automatically released.
Possible values: 0~60 min. (default = 0)
This parameter is available only with CTX Release 1.3 or higher software and with
CTX WinAdmin Release 1.3 or higher software.
Possible values: 20~180 seconds (default = 30)