Bosch DCN Next Generation Operation Manual page 151

Table of Contents

Advertisement

Conference System
6.26
DCN-DDB Data Distribution Board
Use the DCN cable to connect the data distribution board to the DCN. You cannot make a
loop-through in the DCN with the data distribution board.
Notice!
You connect the data distribution board to the DCN with a trunk splitter (LBB4114/00,
LBB4115/00) to bypass the data distribution board.
Figure 6.55: RS232 port, connection
Pin
1
2
3
4
5
6
7
8
9
Table 6.32: RS232 port, connection
Speak slowly signaling
The interpreter desks (refer to DCN-IDESK Interpreter Desks, page 50) have a speak slowly
button. With this button, the interpreters can activate an indicator that tells the current
speaker to speak slowly. This function of the interpreter desk must always be used along with
the data distribution board. Refer to the figure for the physical connections.
Bosch Security Systems B.V.
1
5
6 9
Definition
---
RxD
TxD
---
SG
---
RTS
CTS
---
Operation Manual
Connection | en
Description
Not connected
Receive Data
Transmit Data
Not connected
Signal Ground
Not connected
Request To Send
Clear To Send
Not connected
2013.11 | V2.0 | DCN-NG_OM_V4.x