Chapter 3: Connecting and Configuring the Analysis Probe
Configuring the Logic Analysis System
To load configuration and inverse assembler
files—HP 16600/700 logic analysis systems
If you did not use Setup Assistant, you can load the configuration and
inverse assembler files from the logic analysis system hard disk.
1 Click on the File Manager icon. Use File Manager to ensure that
the subdirectory /hplogic/configs/hp/m683xx/E2480A/ exists.
If the above directory does not exist, you need to install the CPU32
Processor Support Package. Close File Manager, then use the
procedure on the CD-ROM jacket to install the CPU32 Processor
Support Package before you continue.
2 Using File Manager, select the configuration file you want to load
in the /hplogic/configs/hp/m683xx/E2480A/ directory, then click
Load. If you have more than one logic analyzer installed in your
logic analysis system, use the Target field to select the machine
you want to load.
The logic analyzer is configured for CPU32 analysis by loading the
appropriate configuration file. Loading the indicated file also
automatically loads the inverse assembler. The configuration file you
use is determined by the logic analyzer you are using, and whether you
are performing state analysis or timing analysis. The configuration file
names are located at the bottom of the table showing the connections
for your particular logic analyzer. They are also shown in the table on
page 87.
3 Close File Manager.