HP 16600A Series User Manual page 188

Solutions for the motorola cpu32
Hide thumbs Also See for 16600A Series:
Table of Contents

Advertisement

configuration commands in a script.
6 Specify an initialization address for the stack pointer.
This is required if the stack pointer is neither initialized when the
processor is reset nor set in the start-up code generated by the
compiler. If the stack pointer address needs to be initialized:
• In the debugger's command pane, enter:
_INIT_SP = <address>
OR
• In the Target window, enter:
reg a7=<address>
OR
• * Include the following line in an initialization script:
target reg a7=<address>
7 Download the code:
In the Debugger window, select Remote©LoadProgram.
The Debugger command pane indicates that the code has been
downloaded to the target.
Solutions for CPU32
Chapter 8: Using the Emulator with a Debugger
Using the Green Hills debugger
187

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

16700a series

Table of Contents