Symptom
Commands from the Emulation
Control Interface have no effect
Commands from debugger have
no effect
Emulator built-in commands do
not work
"Slow or missing clock" message
after a logic analyzer run
"Slow clock" message in the
Emulation Control Interface or
"c>" prompt in the built-in
"terminal interface"
Some commands fail
Troubleshooting Guide
Common problems and what to do about them
What to do
Check that you are using the correct firmware.
Use the Emulation Control Interface to try a few built-in
commands. If this works, your debugger may not be
configured properly. If this does not work, continue with
the steps for the next symptom....
1 Check that the emulator has been properly configured
for your target system.
2 Run the emulator performance verification tests.
3 If the performance verification tests pass, then there is
an electrical problem with the connection to the target
processor OR the target system may not have been
designed according to "Designing a Target System."
Check that the target system is running user code or is in
reset. (This message can appear if the processor is in
background mode.)
Check that the clock rate is properly configured.
Check the "restrict to real-time runs" configuration
Solutions for CPU32
Chapter 13: Troubleshooting the Emulation Module
Solving Problems
See also