Logic analyzers supported
The table below lists the logic analyzers supported by the HP E2480A
analysis probe. Logic analyzer software version requirements are
shown on the following page.
The HP E2480A requires four logic analyzer pods (68 channels) for
inverse assembly. The analysis probe contains six high-density
connectors (12 logic analyzer pods). Two of the connectors are for
State analysis, and the other four are for Timing analysis.
Logic Analyzers Supported
Logic Analyzer
16600A
16601A
16602A
16603A
16550A (one or two cards)
16554A (one or two cards)
16555A (one or two cards)
16555D (one or two cards)
16556A (one or two cards)
16556D (one or two cards)
16557D (one or two cards)
1660A/AS/C/CS/CP
1661A/AS/C/CS/CP
1662A/AS/C/CS/CP
1670A
1670D
1671A
1671D
1672A
1672D
*For the 16557D, the state and timing speeds decrease for four- or five-card config-
urations.
Solutions for CPU32
Channel
State Speed
Count
204
100 MHz
136
100 MHz
102
100 MHz
68
100 MHz
102/card
100 MHz
68/card
70 MHz
68/card
110 MHz
68/card
110 MHz
68/card
100 MHz
68/card
100 MHz
68/card
135 MHz*
136
100 MHz
102
100 MHz
68
100 MHz
136
70 MHz
136
100 MHz
102
70 MHz
102
100 MHz
68
70 MHz
68
100 MHz
Chapter 1: Overview
Analysis Probe
Timing Speed
Memory Depth
125 MHz
64 k states
125 MHz
64 k states
125 MHz
64 k states
125 MHz
64 k states
250 MHz
4 k states
125 MHz
512 k states
250 MHz
1 M states
250 MHz
2 M states
200 MHz
1 M states
200 MHz
2 M states
250 MHz
2 M states
250 MHz
4 k states
250 MHz
4 k states
250 MHz
4 k states
125 MHz
64 k or .5 M states
125 MHz
64 k or 1 M states
125 MHz
64 k or .5 M
125 MHz
64 k or 1 M
125 MHz
64 k or .5 M
125 MHz
64 k or 1 M
23