Command Line

Configuring the 1/10G Ethernet switch can be done using a command
line via telnet or by using the serial console interface.
Accessing CLI through Telnet:
To access command line via telnet, follow the below steps.
1.
Connect a PC to a network that is accessible to the switch.
For example, connect a PC to any of the front panel ports of the switch
and make sure the PC has an IP address on the same subnet as the
switch management IP.
2.
In the PC, start a telnet client session with the switch management
IP (default IP is 192.168.100.102).
This brings up the switch's command line interface for user login.
3.
Enter username and password to login to the switch.
4.
To view the switch configurations use show commands and to
configure the switch type config term to get access to the
configuration commands. For help type ? or help.