Installation Slot Of Plug-In Boards - Sony HDS-7150 Installation Manual

Hd digital video switcher, power supply unit, switcher control panel, dme control panel
Table of Contents

Advertisement

7-1. Installation of Options for HDS-7150/7100

7-1-1. Installation Slot of Plug-in Boards

The HDS-7150/7100 can be used for various systems, and its functions can be extended by selecting the
optional boards.
Each plug-in board must be installed in the corresponding slot of the HDS-7150/7100. Confirm that all
the boards are in the specified slots.
For the details of how to install the plug-in board, refer to Section 7-1-3.
The board name are displayed near the eject lever at the left side on the A side (component side) of each
plug-in board. The slot number and a name of the plug-in board to be installed in the slot are indicated at
the upper side of the chassis in the HDS-7150/7100. Each optional board should also be installed at the
specified slot according to the slot number as well as the standard board.
Eject lever
Board name
A side (component side)
1
2
3
4
CPU-183 VSE-19 DLP-17 CPU-183
CKG-26
MPU-111
m
. If the board is installed in an incorrect slot, a system error occurs. Then the system is not properly
activated.
. Be sure to confirm the power supply voltage when an optional board is added or a board is replaced.
(Refer to "Section 8 Adjustment of Secondary Power Supply Voltage".)
7-2
6
7
8
9
5
MEM-65
MEM-65
MEM-65
VSE-20 VSE-21
CRK-9
(Y)
(C)
(K)
10
11
12
13
14
MIX-43
KPC-15
VSW-66
DSK-16
WKG-29
CCR-1827
15
16
DI-37
OUT-20
HDS-7150/7100