Loading Trace Files - Siemens SINAMICS S120 Function Manual

Drive functions
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Basic functions
7.30 Web server
The following information is displayed for each drive object:
7.30.7.2

Loading trace files

The Web server permits the loading of trace files created using a multiple trace and stored in
the memory card of the drive. All the files in the "USER/SINAMICS/DATA/TRACE" directory
of the memory card can be loaded to the Web client (i.e. to the PC). The loadable trace files
are displayed on the Web page with their name.
The trace files can be displayed graphically in the commissioning tool.
Note
Activation and parameterization of the multiple trace
Detailed information on the activation and parameter assignment of a multiple trace can be
obtained in the following documentation:
• SINAMICS S120 Commissioning Manual with STARTER
• SINAMICS S120 Commissioning Manual with Startdrive
• STARTER Online Help
• Startdrive Online Help
Here, you can also obtain detailed information about how you can load trace files into your
PC file system.
446
Column
Explanation
DO
Number of the drive object.
DO name
Drive object name
DO type/view
Drive object type
Faults/alarms
Graphical display of the status
Fault
Warning/Maintenance request
Maintenance required
OK
Operating display Drive object status (via r0002)