10.11 Acceptance test and acceptance report
9
10
11
12
13
14
15
16
17
18
19
20
22
23
10.11.4

Acceptance tests

10.11.4.1

General information about acceptance tests

Note
Conditions for the acceptance test
As far as possible, the acceptance tests are to be carried out at the maximum possible
machine speed and acceleration rates to determine the maximum braking distances and
braking times that can be expected.
Note
Non-critical alarms
When evaluating the alarm buffer you can tolerate the following alarms:
• A01697 SI Motion: Motion monitoring test required
• A01796 SI Motion CU: Waiting for communication
These alarms occur after every system startup and can be evaluated as non-critical. You do
not need to include these alarms in the acceptance report.