Download Print this page

Sony BKP-5090 Installation And Maintenance Manual page 66

Camera upgrade board

Advertisement

4-1. Setup Menu (BVP-500 series)
4-1-1. Operation Menu
Page
Ver.
Item
Auto Setup
Auto Black
Auto White
Auto Level
Test
Diagnosis
OHB
PR
VA
AT
SG
DA
IF
MD
AU
TR
Camera ID
No
ID: [] [] [] [] [] [] []
No. / ID On
Bars
Lens File
Center H POS
Center V POS
Center POS
Store
No.
c)
When executing the Auto Level, data set through the menu is all cleared and the automatic level adjustment is performed in
sequence, After the adjustment is complete, adjustment result is stored as a master setup data.
1. A reference file which is reference for adjustment is loaded .
2. Lens is autmatically closed and the black balance is automatically adjusted.
3. The white balance is automatically adjust using Test 2 (3-step) signal.
m
This white balance adjustment compensates a drift of the gain of an amplifier, does not compensate color temperature for an actual object.
The gamma and knee compensation values do not change with a lapse of time because of the digital-processing camera.
Therefore, the gamma and knee compensation values remains the values stored in the reference file.
d)
Fifty kinds of lenses are registered at the factory in the ROM IC26/AT-126 board. Up to 16 of these lenses can be stored as the lens
file in the RAM IC26/AT-126 board. An additional data such as a center marker is also stored in the selected lens file.
4-6 (E)
Settings
Contents
Throw MENU SELECT
Starts to automatically adjust the black balance.
switch to ENTER
(To abort a processing during execution, throw MENU SELECT switch
to execute.
to ENTER.)
Throw MENU SELECT
Starts to automatically adjust the white balance.
switch to ENTER
to execute.
Throw MENU SELECT
Starts to automatically adjust the level in the internal circuits.
switch to ENTER
(To abort a processing during execution, throw MENU SELECT switch
to execute.
to ENTER.)
1, 2, [Off]
Selects the test signal.
1
: Outputs the sawtooth waveform test signal
2
: Outputs 3-step waveform test signal
Off : No test signal is output.
[OK], NG
Displays a state of communication for control data between the OHB
block and CPU on AT board.
[OK], NG
Displays a state of communication for control data between the PR
board and CPU on AT board.
[OK], NG
Displays a state of communication for control data between the VA
board and CPU on AT board.
[OK], NG
Displays a state of communication for control data between the CPU
and memory on AT board.
[OK], NG
Displays a state of communication for control data between the SG
board and CPU on AT board.
[OK], NG
Displays a state of communication for control data between DA board
and CPU on AT board.
[OK], NG
Displays a state of communication for control data between IF board
and CPU on AT board.
[OK], NG
Displays a self-diagnosis result of MD board in connection with CCU.
[OK], NG
Displays a self-diagnosis result of AU board in connection with CCU.
[OK], NG
Displays a self-diagnosis result of TR board in connection with CCU.
1 to 96 ([X])
Sets a camera number in the range of 1 to 96.
(When no camera number is set, "- -" is displayed.)
Sets a camera ID of up to ten alphanumerics, symbols, and spaces.
CAM No., CAM ID,
Selects whether the camera number or ID is mixed with a camera
[Off]
output signal only in the color-bar mode, or not.
(This setting is valid only when the DISPLAY switch is set to ON or OFF)
_20 to 20 ([XX])
Shifts horizontally the location of the center marker on the screen.
20 (right) ↔ _20 (left)
_20 to 20 ([XX])
Shifts vertically the location of the center marker on the screen.
20 (up) ↔ _20 (down)
Throw MENU SELECT
Stores the location of the center marker at present in the selected lens
switch to ENTER
file number.
to execute
[0] to 15
Shows a lens file number. (A lens file appropriate for the mounted lens
is automatically selected.)
(Example)
d)
← Lens file number (0 to15)
No. : 1
← Lens name
Lens:25:A8.5 x 5.5
← Lens extender value
EX: 1.0
c)
BKP-5090

Advertisement

loading