2-3. Adjustments on BVP-500/500P
2-3-9. H Blanking Trailing-edge Phase Adjustment
2-3-9. H Blanking Trailing-edge Phase
Adjustment
Equipment : Oscilloscope
Preparations:
. Install the CN-1672 board to the PR-242 board even if
the 16:9/4:3 switchable OHB is used.
. Extend the DA-88 board with the EX-464 board.
Iris of the lens : CLOSE
Adjustment Procedures:
1. Set the DISPLAY switch/rear panel from OFF to
MENU while pushing up the MENU SELECT switch
to ENTER.
2. Set the menu as follows.
MENU
: Paint
PAGE
: Video Level (P1)
: Black [G] → +99
ITEM
3. Adjustment Point : 1RV1/DA-88 board
Test Point
: TP3 (Y)/DA-88 board
: TP5 (B-Y)/DA-88 board
Specifications
: Adjust the trailing-edge phase
"A" of H blanking as shown
below:
A = 400 ± 100 nS (NTSC)
A = 1100 ± 100 nS (PAL)
Resetting after Adjustment:
Set the menu as follows.
MENU : Paint
PAGE
: Video Level (P1)
ITEM
: Clear
2-20 (E)
TP3 (Y)
TP5 (B-Y)
A