11/2006
9479
MD number
Default setting: 0
Change becomes effective after: POWER ON
Data type: DOUBLE
Significance:
9480
MD number
Default setting: –1
Change becomes effective after: IMMEDIATELY
Data type: BYTE
Significance:
9481
MD number
Default setting: 200
Change becomes effective after: IMMEDIATELY
Data type: INTEGER
Significance:
9602
MD number
Default setting: 100
Change becomes effective after: POWER ON
Data type: LONG
Significance:
9603
MD number
Default setting: 0
Change becomes effective after: POWER ON
Data type: LONG
Significance:
© Siemens AG 2006 All Rights Reserved
SINUMERIK 840D sl Commissioning Manual CNC: ShopMill – 11/2006 Edition
$MM_TO_MAG_PLACE_DISTANCE
Distance between individual tool holders
Min. input limit: 0.0
Protection level: 3/4
You use this MD to specify the spacing between the individual tool holders for the graphical
display of the tools and magazine locations in the tool management.
0 = The tools and magazine locations are not graphically displayed.
Note:
If there are several magazines with different spacing between the tool holders on the ma-
chine, the tools cannot be displayed proportionally to all magazines since there is only one
setting option for the spacing.
$MM_MA_SIMULA TION_MODE
Switch fast view on and off
Min. input limit: –1
Protection level: 3/4
This MD is used to specify whether fast view is always active.
–1 = The ShopMill simulation is displayed.
0 = You can select between ShopMill simulation and fast view .
1 = Fast view is always displayed.
2 = If a program is smaller than the limit specified in the machine data 9481
$MM_STAND_SIMULATION_LIMIT , the ShopMill simulation is called, for larger programs
the fast view.
$MM_MA_STAND_SIMULATION_LIMIT
Limit of the standard simulation in KB
Min. input limit: 200
Protection level: 3/4
With this MD, you specify the size as of which the program loads the fast view.
$MM_CTM_SIMULA TION_DEF_VIS_AREA
Simulation of default display area
Min. input limit: –10000
Protection level: 3/4
This MD defines the size of the display area above the X coordinate. The Y coordinate is
calculated automatically from this setting.
$MM_CTM_SIMULA TION_MAX_X
Simulation of maximum display X
Min. input limit: –10000
Protection level: 3/4
Reserved
7.2
Display machine data for ShopMill
Max. input limit: 10000.0
Units: mm
Valid as of software version
ShopMill 6.3
Max. input limit: 2
Units: –
Valid as of software version
ShopMill 6.4
Max. input limit: 2000000
Units: –
Valid as of software version
ShopMill 6.4
Max. input limit: 10000
Units: mm
Valid as of software version
ShopMill 4.3
Max. input limit: 10000
Units: mm
Valid as of software version
ShopMill 4.3
7 Machine Data
7-49