Making DCU GPI input settings
Use the following procedure.
1
In the DCU>GPI Input Assign menu, using any of the following methods
select what the setting applies to.
• Press directly on the list appearing in the status area.
• Press the arrow keys to scroll the reverse video cursor.
• Turn the knob.
Knob
1
2
In the <Trigger Type> group, select the trigger polarity.
pulse.
high.
No Operation: Apply no trigger on an input pulse.
3
In the <Target Device> group, select the control panel to handle the GPI
input.
SCU1: ID1 control panel (PNL1)
SCU2: ID2 control panel (PNL2)
SCU3: ID3 control panel (PNL3)
The action set in the following step 4 is executed for the switcher and DME
controlled by the selected control panel.
4
Using any of the following methods, select the action you want to set.
• Press directly on the list appearing in the status area.
• Press the arrow keys to scroll the reverse video cursor.
• Turn the knobs.
Knob
2
5
Parameter
Adjustment
No
GPI input
(Rising Edge): Apply the trigger on a rising edge of an input pulse.
(Falling Edge): Apply the trigger on a falling edge of an input
: Apply the trigger on a change in the polarity of the input signal.
(Level): Carry out the specified operation when the input is low or
Parameter
Adjustment
Action
Action selection
Reg No
Register number
Setting values
1 to 50
Setting values
a)
1 to ...
b)
1 to 4
c)
1 to 99
d)
1 to 399