Sony DVS-9000SF User Manual page 320

With ccp-9000 series center control panel
Hide thumbs Also See for DVS-9000SF:
Table of Contents

Advertisement

3
4
5
320
Setup Relating to DME
Knob
Parameter
2
No
In the <Trigger Type> group, select the trigger polarity.
(Rising Edge): Apply the trigger on a rising edge of an input pulse.
(Falling Edge): Apply the trigger on a falling edge of an input
pulse.
: Apply the trigger on a change in the polarity of the input signal.
(Level): Carry out the specified operation when the input is low or
high.
No Operation: Apply no trigger on an input pulse.
In the <Target> group, select what this applies to (channels 1 to 4, or Proc).
Using any of the following methods, select the action to be set.
• Press directly on the list appearing in the status area.
• Press the arrow keys to scroll the reverse video cursor.
• Turn the knobs.
Knob
Parameter
3
Action
4
Reg No
a) • Action list when the trigger type is other than "Level"
When Target is Ch1, Ch2, Ch3, or Ch4: Freeze, SS ? Recall
Effect ? Recall, Effect ? Recall & Run, KF Run, KF Stop, KF Rewind, KF Reverse
Run, No Action
When Target is Proc: No Action
• Action list when the trigger type is "Level"
When Target is Ch1, Ch2, Ch3, or Ch4: Aspect, No Action
When Target is Proc: Format (frame/field rate, number of lines)
Aspect, Level Enable, No Action
Note
"Level Enable" is a function that determines whether GPI inputs are enabled
("Enable") or disabled ("Disable") for the "Aspect" and "Format" actions that can be
used when the trigger type is Level. When "Level Enable" is used, if the input is
"Disable" then it is not possible to switch "Aspect" or "Format" by GPI input.
If a GPI to switch "Aspect" or "Format" occurs when powering the system off, the
action triggered by the GPI may start immediately before the power goes off and the
power may go off before the action is completed. This may corrupt the setup settings.
It is therefore recommended to use "Level Enable" to avoid such a situation.
b) When knob 3 selection is "Snapshot"
Adjustment
Selection of number for action to
be assigned
Adjustment
Action selection
Register number
Setting values
1 to 8
Setting values
a)
1 to ...
b)
1 to 99
c)
1 to 399

Advertisement