Power Loss For Power Units With External Air Cooling - Siemens Sinamics S120 Manual

Booksize power units
Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

Double Motor Modules Booksize
3 A
5 A
9 A
18 A
Double Motor Modules Booksize Compact
1.7 A
3 A
5 A
1)
12.13.5

Power loss for power units with external air cooling

Table 12- 35 Overview of power loss at rated operation for power units with external air cooling (including electronics
losses)
Active Line Modules
16 kW
36 kW
55 kW
80 kW
120 kW
Smart Line Modules
5 kW
10 kW
16 kW
36 kW
55 kW
Single Motor Modules
3 A
5 A
9 A
18 A
30 A
45 A
60 A
85 A
132 A
200 A
Booksize Power Units
Manual, (GH2), 04/2014, 6SL3097-4AC00-0BP6
Power loss at 8 kHz
Unit
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
Unit
W
W
W
W
W
W
W
Internal
External power loss
Power loss
1)
82.8 (60 + 22.8)
200
171 (135 + 36.0)
495
245.6 (200 + 45.6)
700
338.6 (305 + 33.6)
1045
533.2 (490 + 43.2)
1710
41.2 (22 + 19.2)
38
66.6 (45 + 21.6)
75
64.8 (42 + 22.8)
123
116 (80 + 36)
290
185.6 (140 + 45.6)
480
35.4 (15 + 20.4)
15
43.4 (23 + 20.4)
30
55.4 (35 + 20.4)
45
95.4 (75 + 20.4)
90
99.2 (80 + 19.2)
210
135.2 (110 + 25.2)
320
160.2 (135 + 25.2)
455
196 (160 + 36.0)
590
270.4 (250 + 20.4)
1000
455.4 (435 + 20.4)
1615
Cabinet design and EMC Booksize
12.13 Power losses of the components
Power loss
97.6
132.6
187.6
351.2
114
1)
134
1)
194
1)
Total power loss
282.8
666
945.6
1383.6
2243.2
79.2
141.6
187.8
406
665.6
50.4
73.4
100.4
185.4
309.2
455.2
615.2
786
1270.4
2070.4
785

Advertisement

Table of Contents
loading

Table of Contents