Attaching the motor connector to self-fabricated cables

Preparing the power cable
Non-assembled power cables must be appropriately prepared before the motor connector is
connected.
1. Remove the cable sheath to 200 mm ± 5 mm.
2. Fix the braided shield, e.g. with heat-shrink tubing
3. Remove the insulation from the individual U, V, W conductors and the motor holding
brake connecting cables and shorten these corresponding to the drawing shown below.
4. Remove the insulation from the single PE conductor, and crimp this with a ring cable lug
without insulation.
Figure 12-28 Stripped lengths for self-fabricated motor power cables, all data in mm and (inches)