Siemens Sinamics S120 Manual page 433

Booksize power units
Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

Table 6- 31
Technical data Double Motor Modules Booksize (2 x 3 to 2 x 9 A) with 300% overload
External air cooling
Output current
Rated current (l
)
n
Base-load current (I
)
H
Intermittent duty current (I
Peak current (l
)
max
Output voltage
DC-link current I
d max
DC-link voltage
DC-link capacitance
Overvoltage trip
Undervoltage trip
1)
Electronics power supply
Electronics current drawn
at 24 VDC
Current carrying capacity
DC-link busbars
Reinforced DC-link busbars
24 VDC busbars
Unit rating
2)
Based on I
(600 VDC; 4 kHz)
n
Based on I
H
Total power loss
(including electronics losses, see Power loss tables
(Page 781))
Max. pulse frequency
without derating
with derating
Max. ambient temperature
without derating
with derating
Sound pressure level
Cooling air requirement
Max. permissible heat sink temperature
Weight
Default for 400 V line systems; undervoltage trip threshold can be reduced by up to 80 V and is adjusted to the
1)
parameterized rated voltage
Rated power of a typical standard induction motor at 400 V 3 AC.
2)
Booksize Power Units
Manual, (GH2), 04/2014, 6SL3097-4AC00-0BP6
) 40%
s6
6.3 Motor Module with external air cooling
6SL3121-
2TE13-0AA4
A
2 x 3
ACrms
A
2 x 2.6
A
2 x 3.5
ACrms
A
2 x 9
ACrms
V
ACrms
A
7,2
DC
V
DC
μF
110
V
DC
V
DC
V
DC
A
DC
A
DC
A
DC
A
kW
2 x 1.6
kW
2 x 1.4
W
97,6
kHz
kHz
° C
° C
dB(A)
m
/h
3
° C
78
kg
5,8
Motor Modules Booksize
2TE15-0AA4
2TE21-0AA4
2 x 5
2 x 9
2 x 4.3
2 x 7.7
2 x 6
2 x 10
2 x 15
2 x 27
0 ... 480
12
510 ... 720
220
820 ± 2 %
380 ± 2 %
24 (20,4 ... 28,8)
1,15
100
150
20
2 x 2.7
2 x 4.8
2 x 2.3
2 x 4.4
132,6
187,6
4
16
40
55
< 60
29,6
78
5,8
22
220
78
5,7
433