Technical Data - Siemens Sinamics S120 Manual

Booksize power units
Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

Special points to note in relation to mounting on a cold plate
To improve heat transfer, a heat-conducting medium must be used. Special spherical-
indented heat-conducting foil must be used for this purpose. Every Smart Line Module
Booksize Compact is supplied with heat-conducting foil cut to the right size. Note the
mounting position of the heat-conducting foil.
Note
• Also replace the heat-conducting foil when replacing a component.
• Only use heat-conducting foil released or supplied by Siemens.
Table 5- 6
Heat-conducting foil, 100 mm
5.1.8

Technical data

Table 5- 7
Technical data Smart Line Modules Booksize Compact
Smart Line Module Booksize Compact
Rated power
Infeed
Rated power (S1)
1)
Infeed power (S6 - 40 %)
Peak infeed power
1)
Regenerative feedback
Continuous regenerative power
Peak regenerative power
Supply voltages
Line voltage
Line frequency
Electronics power supply
DC link voltage
Overvoltage trip
Undervoltage trip
2)
Input currents
Rated input current
at AC 400 V
Input current
at AC 380 V / AC 480 V
at AC 400 V; S6 - 40 %
at AC 400 V; peak current
Booksize Power Units
Manual, (GH2), 04/2014, 6SL3097-4AC00-0BP6
Heat-conducting foil
1)
5.1 Smart Line Modules Booksize Compact
Order number
6SL3162-6FD01-0AA0
6SL3430–
6TE21-6AAx
kW
16
kW (P
)
16
n
kW (P
)
21
S6
kW (P
)
35
max
kW
16
kW
35
V
3 AC 380 ... 480 ± 10 % (-15 % < 1 min)
AC
Hz
47 ... 63
V
24 (20.4 ... 28.8)
DC
V
510 ... 720
DC
V
820 ± 2 %
DC
V
360 ± 2 %
DC
A
27.5
AC
A
29 / 24.5
AC
A
35
AC
A
57.5
AC
Line Modules Booksize Compact
359