Cabinet design and EMC Booksize
12.8 Connection systems
12.8.6
Motor connection connector
Motor Modules 3 A to 30 A are supplied without a motor connector. Prefabricated MOTION-
CONNECT power cables with pre-assembled motor connectors or unassembled power
cables can be used to connect motors. In this case, the motor connector must be ordered
separately.
The motor connector is equipped with a locking mechanism. Mounting on the Motor Module
is described in the following.
12.8.6.1
Mounting on the Motor Module
Motor connectors with locking mechanism are available in two versions:
● Crimp plug for pre-assembled motor cables
● Screw connector for motor cables that need to be assembled
The way in which motor connectors are installed depends on the type of Motor Module used.
Note
With Double Motor Modules, the rear motor connector must be installed first and then
locked.
Installation on Motor Modules without pre-assembled interlock bolt
Figure 12-26 Installation example: Crimp plug
746
Booksize Power Units
Manual, (GH2), 04/2014, 6SL3097-4AC00-0BP6