Siemens SINUMERIK 840D sl Operating Manual page 341

Sinumerik integrate create myconfig - diff, expert, topo
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Automatic configuration
The step-by-step commissioning is possible only to a limited
extent (e.g. the addition of DQI/SMI motors).
The specification of the comparison topology file allows the
DRIVE-CLiQ wiring to be checked.
Configuring in Expert
When configuring in Expert, on the "System configuration" dialog page in section "DRV..."
under "Origin of data", you can define which of the four applications "Initial state,"
"Automatic configuration," "User-specified topology," or "Offline archive" is applicable.
By selecting the "User-specified topology" mode, it is necessary to generate with Topo a file
with the user-specified topology and make it available to the package for execution on the
"SINAMICS topology" dialog page. The user-specified topology file has a binary format with
the file extension "utz."
If "automatic configuration" is performed, as an option, you can use on the "SINAMICS
topology" dialog page a file with the comparison topology in XML format and the file extension
"ust" or "xml". This is used for comparison with the automatically detected topology.
The two topology files can be configured in one package. During execution, the setting Origin
of data" under "DRV archive data/drive configuration on the "System configuration" page
determines which of the two settings will be used on the following "SINAMICS topology" page.
Both the user-specified topology and the comparison topology contain the topology of the
SINAMICS and other properties of the DOs and the components.
Figure 4-117 CMC package structure
SINUMERIK Integrate Create MyConfig - Diff, Expert, Topo
Operating Manual, 11/2016, A5E36537479B-AD
4.13 SINAMICS device configuration
User-specified topology
The step-by-step commissioning is possible almost without
limitation (e.g. the addition of DQI/SMI motors).
The SINAMICS reports an error if the topology specified in
the user-specified topology cannot be implemented.
Create MyConfig - Expert
341

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 828d

Table of Contents