10 | Analog and Frequency Inputs
76 / 160
A 'Multipoint Adjustment Wizard' opens.
4. To activate the internal pullup‐resistor, check the box. The internal pullup‐re‐
sistor is used to get a 5 V signal at the analog channel of the DDU 7. It allows
you to use a push‐button. The fixed value of the internal pullup‐resistor is
3.01 kOhm. If using an additional external pullup‐resistor, set up the overall
resistance.
5. Click 'Next' when done.
The second part of the 'Multipoint Adjustment Wizard' opens.
Physical
(channel)
value
6. Click 'Next' when done.
The third part of the 'Multipoint Adjustment Wizard' opens.
DDU 7 Manual
Choose unit group
and unit of physical
value
Select type of curve
Enter physical
adjustment values
her (can still be
edited later)
Electrical (pin) value
Bosch Motorsport