8 | Display Configuration
Notice
36 / 160
2. Switch to the tab 'Alarm representation'. It is configured in the same way as
the 'Alarm' text display element.
a)
b)
c)
d)
e)
a) Select the image from the hard drive that is shown in case of an alarm.
b) Choose the condition when the alarm will be activated:
- Create a condition using the Condition Creator. For more information see chapter
'Creating a new condition channel'
- Choose an existing condition
The 'Alarm Icon' is displayed if function is 'TRUE'; i.e. result of the calculation is >0.
c) Enable the checkbox if you want to define parts of the image as transparent.
d) Select the basic transparent color key. This means that any pixel of the amage near (depending of the
tolerance value) to this color gets transparent.
e) Select a tolerance in percent to define parts of the mage as transparent.
3. Click 'OK' when done.
If several active alarms in the display overlap, each alarm is in
the foreground for 2 seconds.