13 | Recording and Telemetry
13.2.6
114 / 160
Displaying online recording diagnosis
('statectrl_ok')
1. To add a Recording Diagnosis element to a measurement sheet, change to
page "Calibration/Measuring" and drag a 'Bit‐LED' element from the Toolbox
and drop it on measurement sheet.
2. Drag channel 'statectrl_ok' from the Data Area and drop it on the 'Bit‐LED' el‐
ement.
The 'Bit‐LED' element shows the state of received channel data in bit‐representa‐
tion. A green highlighted channel means 0, a red highlighted channel means 1.
▪ Measurement correctly initialized, but recording threshold(s) not reached:
254
▪ Measurement correctly initialized, DDU 7 is recording data: 255
▪ Values less than 254 indicate an error state
▪ 'statectrl_ok' can be linked to an alarm on the display. See chapter ''Alarm'
display element
[}
33]' for details.