No
Option
10
ITP VERS
UPGRADE
11
MGI ALIVE
PERIOD
12
DATA CARD IPC
13
ITP RING
VOLUME
14
ITP MAX TX LIMIT
15
WIP DSP PARA
16
ALL IDLE ITP OUT
23
PUBLIC IP SET
© SAMSUNG Electronics Co., Ltd.
OfficeServ 7000 Series Call Server Programming Manual
Description
1. START (HHMM): IP-based phone software
automatic upgrade start time.
2. INTERVAL: IP-based phone software automatic
upgrade interval time.
Set the time interval of checking the link connection of
MGI card and the system.
Designate whether to execute the IPC with the DATA
card if the DATA card is mounted on the system.
Designate the Ring Volume value of the IP phone as
eight stages.
TX level which is in case of using MGI or not can be
restricted for voice quality of IP Phone.
Designate the DSP parameter of the WLAN phone
- M-FRAME: The length of voice data.
- ECHOCNCL: The option for using Echo Cancel
function.
All IP-based phone supporting IDLE MODE can logout
except IP LOUT COS is limited and phone is busy
state.
Type :
0) MMC COMMAND : All IP-based phone logout
manually only.
1) AUTO TIME : All IP-based phone logout
automatically at set time.
TIME (HHMM) : All IP-based phone automatic logout
time.
LOGOUT NOW : All IP-based phone logout now.
No
MMC830
1 (IP SET 1)
SYS
PUBLIC IP1
2 (IP SET 2)
SYS
PUBLIC IP2
3 (IP SET 3)
SYS
PUBLIC IP3
MMC831
MMC843
PUB IP1
PUB IP1
PUB RTP1
PUB RTP1
PUB IP2
PUB IP2
PUB RTP2
PUB RTP2
PUB IP3
PUB IP3
PUB RTP3
PUB RTP3
(Continued)
Default
2222
(Disable)
10 seconds.
05 SEC
YES
LEVEL 1: 02
LEVEL 2: 03
LEVEL 3: 04
LEVEL 4: 05
LEVEL 5: 06
LEVEL 6: 07
LEVEL 7: 08
LEVEL 8: 09
NO
40MSEC
ENABLE
0
22:00
NO
1(IPSET 1)
2-397