Bosch MIC612 Operation Manual page 71

Hide thumbs Also See for MIC612:
Table of Contents

Advertisement

MIC612 Thermal Camera
PTZ Setup Menu Choices:
Menu
Exit
Edit Tour 1
Edit Tour 2
Tour 1 Period
Tour 2 Period
Scan Speed
Edit Presets
Limit Stops
Recordings
AutoPivot
Bosch Security Systems
Description
Exits the menu.
Accesses the Add /
Remove Scenes On
Standard Tour 1 Menu.
Accesses the Edit Custom
Tour Menu.
Changes the length of
waiting time between
presets.
Changes the length of
waiting time between
presets.
Changes the Autopan and
AutoScan speeds.
Modifies preset scenes.
Toggles the Limit Stops for
AutoScan.
Selects record Pattern 1 or
2, if normal pattern
command does not
respond.
Follows a subject while
beneath the camera,
without inverting the
picture.
Operation Manual
On-Screen Display (OSD) Menus (Pelco Protocol) | en
Sub-menu / Description
Exit: Exits the menu.
Scene (1 - 5): Adds or removes
scenes from the Standard Tour.
Exit: Exits the menu.
Scene (1 - 5): Adds or removes
scenes from the Custom Tour.
Sliding scale: – (3 sec. to 10 min.) + 5 sec.
Sliding scale: – (3 sec. to 10 min.) + 5 sec.
Sliding scale: – (1°/sec to 60°/sec)
+
1-99 scenes
ON or OFF
"A" or "B"
ON or OFF
71
Default
Setting
30°/
sec.
OFF
"A"
ON
2016.03 | 2.2 | F.01U.249.416

Hide quick links:

Advertisement

Table of Contents
loading