Earth Link On Pcb - Bosch MIC612 Operation Manual

Hide thumbs Also See for MIC612:
Table of Contents

Advertisement

16
en | Install the MIC (standard) PSU
Figure 5.3: Exploded View of Composite Cable Connections
Camera
Cable
Connector
Pin
1
2
3
4
5
6
7
8
9
10
11
12
13
5.4

Earth Link on PCB

The printed circuit board (PCB) of each MIC PSU (IR and non-IR) has one Earth Link option,
near terminal block HD1, to allow the PSU to be set up for different earthing schemes:
2016.03 | 2.2 | F.01U.249.416
Signal Name
Washer Drive Rtn
Tamper Sw Rtn
Washer Drive
Tamper Sw
Video Return
Video Output
Full Duplex Tx B+
Full Duplex Tx A-
0v
Full Duplex Rx A-
Half Duplex Tx/Rx A
Full Duplex Rx B+
Half Duplex Tx/Rx B
Power Input 2
Power Input 1
If there is a separate connection between video screen and earth, the Earth Link should
be broken. This usually occurs on copper-connected systems where all of the copper
video coaxes are taken back to the control room to be connected to a central earth point.
If fiber optics or other indirect connections are used to get data and video to and from
the control room, then the Earth Link should be left intact, as long as it is the only
camera-end earth reference point.
Description
Auxiliary Connection
Auxiliary Connection
Wash Signal
Alarm Communications
Video Signal Ground
Video Output to Control Room
Telemetry I/O to RS-422/485
Telemetry I/O to RS-422/485
Ground
Telemetry I/O to RS-422/485
Telemetry I/O to RS-422/485
Low Voltage Power Input
Low Voltage Power Input
Operation Manual
MIC612 Thermal Camera
Cable Wire
Color
Grey
Brown
Orange
Black
Coax
Screen
Coax Core
Violet
Blue
Shield
Yellow
White
Green
Red
Bosch Security Systems