Bosch MIC612 Operation Manual page 26

Hide thumbs Also See for MIC612:
Table of Contents

Advertisement

26
en | Install the MIC (standard) PSU
Signal
Washer
Pump
Washer
Pump
Warning!
!
The washer pump terminal is rated only to 24 VAC or VDC maximum voltage and is not
suitable for Mains-operated pumps.
4
28. After wiring is complete, connect the power supply to the power source.
29. Verify that the following LEDs are lit:
LED
LED 2
LED 4
LED 3
LED 5
2016.03 | 2.2 | F.01U.249.416
Pin
Number
1
2
Test the washer by pressing the red button marked SW1 PUMP ON on the PCB.
LED 3 illuminates in response to telemetry commands from the control room to turn on
the washer. Note that the software in the camera prevents the washer from running more
than 10 seconds continuously to prevent emptying the washer bottle.
Description
18 VAC power on to camera
Power on for optional heater
18 VAC power on camera
Power on for optional heater