en | On-Screen Display (OSD) Menus (Bosch Protocol)
Multi Alarm Setup
Allows setup of multiple alarms. Options: On; Off. Checkbox button to "Select."
Inputs Setup Submenu Choices:
Inputs Setup
Defines physical inputs or events and commands that can be used in a rule. There are twelve
(12) alarm inputs available.
Inputs 1-8
Defines the type of physical input (dry contact): N.O. (Normally Open) (default setting) or N.C.
(Normally closed).
Inputs 1–4 are available for Standard and IR models.
Inputs 5–8 are available for Standard models with optional alarm card installed.
Inputs 9-12
Defines input commands that can be used in a rule. Command inputs can also be customized
by using non-assigned keyboard command numbers.
Option
NONE
Aux On Responds to a standard or custom keyboard ON (1-99) command.
Aux Off Responds to a standard or custom keyboard OFF (1-99)
Shot
On models with the 35 mm thermal lens, you can also select either High Temp Thermal Meter
or Low Temp Thermal Meter, to trigger an alarm on the OSD if the thermal spot meter
identifies that the temperature of an object in the view of the camera is outside of the
temperature threshold set in the system. By default, the option is "Not Set." For more details,
see Section 8.4 Triggering Alarms On Detection of Objects Outside of Set Thermal Temperature
Threshold, page 58.
2016.03 | 2.2 | F.01U.249.416
Description
(Default setting) No command defined.
command.
Responds to a Preset shot or scene from 1-99.
Operation Manual
MIC612 Thermal Camera