Figure 5-30: Engaging the Prongs in the Circulation Pump Impeller

5. Carefully turn the releasing tool back and forth about its axis to release the pump
impeller. See Figure 5-31.

Figure 5-31: Turning the Circulation Pump Tool

Note:
The circulation pump releasing tool (P/N 05585740) can be obtained by contacting
the Miele Technical Support Center at (800) 999-1360.
5.39

Heater Pressure Switch (B1/10) Removal

1. Remove as much water as possible from the sump.
2. Lay the dishwasher on its back.
3. Remove the drip pan. See Section 5.29.
4. Disconnect the electrical connection.
5. Unlock the heater pressure switch by turning it approximately 90°
counterclockwise (Figure 5-32, Item 1), then remove it (Figure 5-32, Item 2).