6.8.12.3.1 Accessing Fault Codes; Table 6-64: G 898 Service Mode 2 Functions; Table 6-65: G 898 Fault Code Chart - Miele G 600 Series Technical Information

(all us models)
Hide thumbs Also See for G 600 Series:
Table of Contents

Advertisement

Technical Information
1. To access Service Mode 2, close the door and turn the dishwasher on. All
program lights should light. If not, press the Start/Stop button to cancel the
program. Turn the dishwasher off.
2. Press and hold the Top solo and Start/Stop buttons while turning the
dishwasher on. Successful accessing of Service Mode 2 is indicated by a dot (.)
in the display and flashing Drain and Salt lights.
3. Press the appropriate program button indicated in Table 6-64 to modify the
corresponding function.
4. Use the Top solo button to toggle through the function settings.
5. To save: Press the Start/Stop button twice and turn the dishwasher off.
Program button
Pots & Pans
Sani Wash
Normal Plus
Normal
China/Crystal
Light Wash
Economy
Short
Energy saver

Table 6-64: G 898 Service Mode 2 Functions

1
Factory setting

6.8.12.3.1 Accessing Fault Codes

1. Access Service Mode 2.
2. Press the Pots & Pans program button.
3. The fault code will be shown in the display, e.g., F01, F02, etc.
4. Use the fault chart (Table 6-65) to determine which fault has been stored in the
dishwasher.
5. Turn the dishwasher off.
Fault code
F00
F01
F02
F03
F04
F05
F06
F07
F08
F09

Table 6-65: G 898 Fault Code Chart

Function
Fault codes
Operating hours
Operating hours
EGS
Increase temperature
Water softener
Increase water level
Interim rinses
1
Extended drying
Fault
No error
NTC or NTC connections open-circuited
NTC or NTC connections short-circuited
Electronic failure, selector switch position not found
Heating failure - heating circuit opened or defective
electrical component in heating circuit
Water drainage failure, heater level switch
Too few pulses at flow meter / start of water intake
Too few pulses at flow meter / end of water intake
Water intake failure, heater level switch
Heater level switch not switching on at the end of thermal stops
124
Options
Display
-
F00, F01, etc.
-
e.g., 001
-
e.g., 127
On
40
Off
41
150°F
50
160°F
51
1
With
60
Without
61
Standard
70
Increased
71
1
80
2
81
14 minutes
90
45 minutes
91
G 600/G 800

Advertisement

Table of Contents
loading

Table of Contents