G 600/G 800
Program
Rinse & Hold
Pots & Pans
Table 6-51: G 892, G 832 Service Mode 2 Functions
1
Can only be set if "+14 min" is selected in programming mode. See Section 6.8.9.1.2.
6.8.10
G 694, G 894
Enter Programming Mode
Enter Service Mode 1
Enter Service Mode 2
Table 6-52: G 694, G 894 Programming Flow Chart
6.8.10.1
Programming Mode
1. To access the programming mode, close the door and turn the dishwasher on.
The Start/Stop light must be blinking. If the Start/Stop light is not blinking, press
and hold the Start/Stop button for at least 3 seconds to exit the cycle. The
Start/Stop light should now be blinking.
2. Turn the dishwasher off.
3. Press and hold the Top solo and Start/Stop buttons while turning the
dishwasher on. Successful accessing of the programming mode is indicated by
a blinking Salt light.
4. The display will show the current water hardness setting. The "A" indicates
Aqua and the numbers indicate the hardness setting.
Note:
If the display is blank, the appliance has been programmed for "without softener".
See Service Mode 2 (Section 6.8.10.3) to turn the water softener on or off.
Function
1
Extended drying
EGS
Programming Flow Chart
To access:
Water hardness settings
Extended drying fan time (+14 minutes)
To access:
Manual step mode
Component test program
To access:
Error messages
Program index
Increased water temperature selection
Water softener (with/without)
Interim rinses
Extended water intake
Extended drying fan time (+ 45 minutes)
EGS
115
Technical Information
Options
Program light status
Off
Flashing
On
Lit
On
Flashing
Off
Lit