5. Remove the restrictor with needlenose pliers; see Figure 5-23.

Figure 5-23: Removing the Flow Restrictor

6. Install the new restrictor using a suitable 5mm nut driver.
Note:
Use care when installing a new flow restrictor. A damaged restrictor should never be
used.
5.26

Water Inlet (Diverter) Removal

1. Open the door.
2. Unscrew the connections securing the water inlet to the inside of the cabinet; see
Figure 5-24.

Figure 5-24: Water Inlet Removal

3. Remove the right side panel. See Section 5.3.
Note:
Be prepared, as residual water will remain in the water inlet and will flow out of the
inlet once hoses are disconnected.
4. Disconnect all connection hoses.
5. Remove the water inlet.