Accessing Fault Codes; Table 6-16: G 811, G 851, G 851 Plus, G 856, G 856 Plus Service Mode 2 Functions; Table 6-17: G 811, G 851, G 851 Plus, G 856, G 856 Plus Fault Code Chart - Miele G 600 Series Technical Information

(all us models)
Hide thumbs Also See for G 600 Series:
Table of Contents

Advertisement

Technical Information
3. Press and hold the Top solo button while turning the dishwasher on. Release
the Top solo button and immediately press it 2 more times. Flashing
Intake/Drain and Salt lights indicates successful accessing of Service Mode 2.
4. Turn the program selector switch to the appropriate position in Table 6-16 to
access the various functions of Service Mode 2. Press the Top solo button to
toggle functions on or off.
Selector switch position
1 o'clock
2 o'clock
4 o'clock
5 o'clock
6 o'clock
7 o'clock
8 o'clock
9 o'clock
10 o'clock

Table 6-16: G 811, G 851, G 851 Plus, G 856, G 856 Plus Service Mode 2 Functions

6.8.3.3.1

Accessing Fault Codes

1. Access Service Mode 2.
2. Turn the program selector switch to the 1 o'clock position. The Top solo light will flash.
3. Press the Top solo button once.
4. If the Top solo light is lit, no fault has been stored. If the light is not lit, turn the selector
switch slowly clockwise until the Top solo light lights up.
5. Use the fault chart (Table 6-17) to determine which fault has been stored in the dishwasher.
6. Turn the dishwasher off.
Selector switch position
1 o'clock
2 o'clock
3 o'clock
4 o'clock
5 o'clock
6 o'clock
7 o'clock
8 o'clock
9 o'clock
10 o'clock

Table 6-17: G 811, G 851, G 851 Plus, G 856, G 856 Plus Fault Code Chart

Function
Fault codes
Program index
EGS
Increase temperature
Water softener
Increase water intake
2 interim rinses
Extended drying fan
time
Dishwasher width
Fault code
Fault
F00
No error
F01
NTC or NTC connections open-circuited
F02
NTC or NTC connections short-circuited
Electronic failure, selector switch position not
F03
found
Heating failure - heating circuit opened or
F04
defective electrical component in heating circuit
F05
Water drainage failure, heater level switch
Too few pulses at flow meter / start of water
F06
intake
Too few pulses at flow meter / end of water
F07
intake
F08
Water intake failure, heater level switch
Heater level switch not switching on at the end
F09
of thermal stops
92
G 600/G 800
Options
Start light status
See Table 6-17
Flashing
See Table 6-18
Flashing
On
On
Off
Off
150°F
Off
160°F
On
With
Off
Without
On
On
On
Off
Off
Without
Off
With
On
Off
Off
On
On
24"
Off
18"
On