6.8.13.3.1 Accessing Fault Codes; Service Mode 2; Table 6-71: G 803, G 643, G 843, G 663, G 863 Service Mode 2 Functions - Miele G 600 Series Technical Information

(all us models)
Hide thumbs Also See for G 600 Series:
Table of Contents

Advertisement

Technical Information
6.8.13.3

Service Mode 2

Service Mode 2 is used to determine which upper electronic is in the appliance, to
change certain programmed functions and to access fault codes. The programmed
functions include increasing the water temperature, turning on or off the water
softener, adding an interim rinse, and setting the dishwasher width (18" or 24").
1. To access Service Mode 2, open the dishwasher door and turn the dishwasher off.
2. Press and hold program buttons 2 and 3 while turning the dishwasher on.
Successful accessing of Service Mode 2 is indicated by flashing Salt and
Intake/Drain lights.
3. Illuminated program button lights will indicate the current program settings (see
Table 6-70).
4. The settings can be changed by using program buttons 1 to 5. To change the
settings, press the corresponding program button indicated in Table 6-70.
5. To save: Press the program button 6 twice.
Program button
1
2
3
4
5

Table 6-71: G 803, G 643, G 843, G 663, G 863 Service Mode 2 Functions

1
Factory setting

6.8.13.3.1 Accessing Fault Codes

1. Access Service Mode 2.
2. Press the flashing program button 5.
3. Press the flashing program button 1.
4. One of the program button lights (1 to 5) will light up, indicating a stored fault code of F0 -
F4. If none of the program buttons light, a fault code of F5 - F9 is stored. To display fault
codes F5 - F9, press program button 6 once. Program button 6 will light up along with
one of the other program buttons (1 to 5). See Table 6-72.
Program button 6
Not pressed
Not pressed
Not pressed
Not pressed
Not pressed
Pressed
Function
Options
150°F
Increase water
temperature
160°F
With
Water softener
Without
With
2 interim rinses
Without
24"
Dishwasher width
18"
Program index
-
Fault codes
-
Program button
Fault code and description
light
1
F00
2
F01
3
F02
4
F03
5
F04
1
F05
128
Program button light
Off
On
1
Off
On
Off
On
Off
On
Off
On
No error
NTC or NTC connections open-circuited
NTC or NTC connections short-circuited
Electronic failure, selector switch
position not found
Heating failure - heating circuit opened
or defective electrical component in
1
heating circuit
Water drainage failure, heater level
switch
G 600/G 800